Olympus OER-Pro Endoscope Reprocessor Scope Washer
Couldn't load pickup availability
Listing Terms & Conditions
All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.
The Olympus OER-Pro is an automated endoscope reprocessor designed by Olympus to provide high-level disinfection for flexible endoscopes and accessories.
Overall, the Olympus OER-Pro is a reliable and efficient automated endoscope reprocessor that ensures high-level disinfection for flexible endoscopes, reflecting Olympus's expertise in the field of endoscopy equipment.
FEATURES:
- Design:
- The OER-Pro is specifically designed by an endoscope manufacturer, Olympus, with 35 years of experience in flexible endoscope reprocessor manufacturing.
- Functionality:
- It offers high-level disinfection for Olympus flexible endoscopes and accessories, ensuring optimal reprocessing outcomes.
- Efficiency:
- The OER-Pro has a quick reprocessing time, capable of simultaneously reprocessing two flexible endoscopes in 26-29 minutes.
- Compact Design:
- With a smart and compact design, the OER-Pro requires less space than conventional endoscope reprocessors, making installation and maintenance easier.
- Disinfectants:
- It can be used with two dedicated high-level disinfectants: Acecide-C and ALDAHOL 1.8, both tested and approved by Olympus for compatibility with their endoscopes.
- Data Management:
- The OER-Pro offers electronic data management solutions to simplify data input, streamline record keeping, and reduce the need for paper receipt searches.
SPECIFICATIONS:
- Manufacturer: Olympus
- Part Number: (OEM): OER-Pro
- Category: Endoscope - Systems
- Condition: Refurbished
- Weight: 265lbs.
- Warranty: 3 Months
- Dimensions:
- 450(W)x977(H)x765(D)mm
- 450(W)x977(H)x765(D)mm
- Weight:
- 120 kg (dry condition)
- 120 kg (dry condition)
- Power Supply:
- Voltage 120 V AC
- Frequency 60 Hz
- Input current 5.5 A
- Voltage fluctuation ±10%
- Ultrasonic Wave:
- Frequency 36 ±2 kHz
- Power 100 W ±20%
- EMC:
- Applied Standard:
- IEC 61326: 2012
- This equipment complies with the standards listed in the left column.
- CISPR 11 of emission:
- Group1,Class B
- Applied Standard:
- Electrical Safety:
- Applicable Standard:
- UL 61010-1: 2012
- CSA C22.2
- No. 61010-1: 2012
- CSA C22.2
- No. 61010-2-040: 2007
- IEC 61010-1: 2010
- IEC 61010-2-040: 2005
- This equipment complies with the standard listed in the left column.
- Installation category: II
- Pollution degree: 2
- Applicable Standard:
- Radio Transmitter:
- Compliance
- ISO/IEC 18000-3 (Mode1)
- Center Frequency
- 13.56 MHz
- Modulation
- ASK
- Effective Radiated Power
- 300 mW±20
- 300 mW±20
- Compliance
- Shipping Environment:
- Ambient temperatures –47 to +60°C (–52 to +140°F)
- Relative humidity 10 – 90%
- Atmospheric pressure 700 – 1060 hPa
- Operating Environment:
- Ambient temperatures 10 – 40°C (50 – 104°F)
- Relative humidity 30 – 85%
Elevation 3000 meters (Maximum) - Designed for use Indoors
- Water supply flow 17 l/min. or more when the water faucet is fully open
- Water supply pressure 0.1 – 0.5 MPa (include water hammer)
- Water supply temperature: Max. 28°C
- Water type Potable water or Softened water (Purified water cannot be used)
- Water hardness 400 ppm (maximum)0 – 150 ppm (Recommended value)
- Compatible Scopes:
- Olympus Flexible Endoscopes:
- (Refer to the “List of Compatible Endoscopes/Connecting Tubes <OER-Pro>” for details)
- The OER-Pro does not sterilize endoscopes.
Therefore, after cleaning/disinfecting an endoscope
that requires sterilization, always sterilize the
endoscope as instructed in its instruction manual.
- Olympus Flexible Endoscopes:
- Number of Reprocessed Scopes:
- Maximum 2 (1 w/ certain models)
- Maximum 2 (1 w/ certain models)
- Cleaning Method:
- Exterior surfaces Ultrasonic cleaning, turbulent bath
- Channel interiors Fluid flushing
- Valves Ultrasonic cleaning, fluid flushing
- Disinfection Method:
- Exterior surfaces Disinfectant solution immersion
- Channel interiors Disinfectant solution flushing and filling
- Valves Disinfectant solution immersion
- Cleaning Time Setting:
- 3 – 10 minutes (Setting variable in
- 1 min. increments)
- Disinfection Time Setting:
- Concentrated disinfectant solution
- 7 minutes
- Ready-to-use disinfectant solution
- 10 minutes
- 10 minutes
- Concentrated disinfectant solution
- Disinfectant Solution Heating Setting:
- 20°C (68°F)
- (If the temperature of disinfectant solution is below 20°C, it is heated to 20°C (68°F).)
- (If the temperature of disinfectant solution is below 20°C, it is heated to 20°C (68°F).)
- 20°C (68°F)
- Disinfectant Solution Heating Method:
- Built-in heater in the reprocessing basin.
- Heating immediately before disinfection process in a reprocessing program
- Heating before the start of a reprocessing program
- Built-in heater in the reprocessing basin.
- Water Discharge Method:
- Forced draining using a pump (Floor draining)
- Forced draining using a pump (Floor draining)
- Disinfectant Solution Discharge Method:
- Draining through disinfectant
collection hose - Draining through drain hose
- Draining through disinfectant
- Reprocessing Basin Capacity:
- Approximately 14L
- Approximately 14L
- Disinfectant Solution Tank Capacity:
- Approximately 17.5L
- Disinfectant Solution:
- Olympus-validated disinfectant solution
- Olympus-validated disinfectant solution
- Detergent:
- Olympus-validated detergent
- Olympus-validated detergent
- Visual Leakage Detection:
- Bubble detection during immersion
- Bubble detection during immersion
- Alcohol Flushing:
- Automatic flushing/draining using a pump and compressor
In addition please acknowledge the following disclaimer:
* IMPORTANT - PLEASE READ BEFORE PURCHASING! * All pictures of items being sold are used for reference purposes and are described as accurately as possible. If there is an error in a listing, we will try and resolve any issues to the best of our abilities that may arise before or after a sale. Complete units all come with a power cord and DO NOT come with any cables, sensors, manuals, accessories etc. unless otherwise noted in the description.
Purchaser agrees that seller is not liable for any injuries or damages of any kind associated in any way with this equipment. Purchaser agrees to indemnify and hold harmless seller and seller's officers, directors, employees, agents, and shareholders against any and all claims, liabilities, obligations, demands, cost and expenses of every kind and nature, including but not limited to attorney's fees and litigation expenses, from or related to the equipment and any use thereof.
* NOTE - FDA Regulation and Certification: "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item."