GE OEC 9900 C-Arm
Couldn't load pickup availability
Listing Terms & Conditions
All product and company names are trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement or sponsorship by them.
The OEC 9900 is a mobile C-arm system manufactured by GE Healthcare. It is designed to provide high-quality imaging for a variety of medical procedures, including vascular, neurovascular, and cardiac applications. The system features advanced technology such as Dynamic Range Management, Motion Tolerant Subtraction, and high-resolution imaging capabilities. It also offers different configurations and optional packages tailored to specific medical fields.
The OEC 9900 is known for its ease of use, intuitive interface, and flexibility in positioning patients. It is a widely used and respected system in the medical imaging field, known for its excellent image quality and innovative features.
FEATURES:
The OEC 9900 offers several improvements and additional features compared to the OEC 9800. Some of the key differences include:
- Image Quality:
- The OEC 9900 provides higher image resolution compared to the OEC 9800, which can be beneficial for various procedures, including orthopedic, gastrointestinal, endoscopic, urologic, neurologic, critical care, emergency, and vascular procedures.
- Monitors:
- The OEC 9900 is equipped with flat panel monitors on an articulating arm, offering advanced articulation and improved ergonomics. The monitors are also of higher resolution than those of the OEC 9800.
- Software Features:
- The OEC 9900 offers improved software features, such as preset imaging profiles, dynamic range management, and remote service connectivity.
- Hardware and Storage:
- The OEC 9900 has more modern hard drives with larger capacity and improved storage options compared to the OEC 9800.
- Touchscreen Technology:
- The touchscreen technology of the monitors on the OEC 9900 is also improved compared to the OEC 9800.
- X-Ray Tube and Generator:
- Both systems have similar X-ray tube, generator, image intensifier, steering, hardware, and C-arm movements.
In summary, the OEC 9900 offers enhanced image quality, improved monitors, advanced software features, and modern hardware compared to the OEC 9800. These improvements make the OEC 9900 well-suited for a wide range of surgical needs and procedures.
OEC 9900 SPECIALTY PACKAGES AVAILABLE:
- GSP (General Surgical Package) Platform:
- 1k x 1k x 16 bit image processing
- Preset Imaging Profile
- 9800
- General
- Orthopedic
- Spine
- Noise filter with on-screen indicator
- Minimal difference spatio-temporal noise filter (MDST)
- Real time dynamic range management (DRM)
- Automatic digital brightness and contrast control
- Manual digital brightness and contrast control
- Negate mode
- Save and auto-save feature
- Swap and auto-swap feature
- Patient information
- Examination list
- Customized patient information
- Customize functions
- Workstation set-up
- Mainframe set-up
- Patient information set-up
- Date/time set-up
- DICOM interface set-up
- Last image hold
- 63 image storage
- CD/DVD burner with DICOM viewer for displaying images on PC platforms
- 512 x 512 or 1k x 1k
- Integrated DICOM interface (store, print, worklist, and query/retrieve)
- HIPAA SecureView®
- Password protection
- Blank screen function
- ESP (Expanded Surgical Package) Platform:
- Includes all the GSP features and:
- 1000 image storage
- Zoom and roam function
- Image annotation
- Measurement software
- ESP 15 FPS
-
Includes all the ESP features and:
- 15fps Dynamic digital disk (60 Hz) 12fps (50 Hz)
- Recording/playback rate: 1, 2, 4, 8, 15fps (60 Hz) 12fps (50 Hz)
- Automatic image playback capability
- Frame-by-frame review
- Recording time: 10 minutes @ 15fps (60 Hz) 12 fps (50 Hz)
- PM Care Platform:
- Includes all the ESP features and:
- Real-time subtraction
- Digital subtraction (DSA) angio
- Peak opacification
- 8fps Dynamic digital disk
- Recording/playback rate: 1, 2, 4, 8fps
- Recording time: 5 minutes @ 8fps
- Automatic image playback
- Frame-by-frame review
- Basic Vascular Platform:
- Includes all the PMCare features and:
- Vascular preset imaging profile
- Roadmapping
- Re-registration
- Variable landmarking
- Mask save/recall
- Vascular MTS Platform:
- Includes all the Basic Vascular features plus Motion Tolerant Subtraction (MTS) and:
- Bolus chase preset imaging profile
- Digital cine pulse mode
- 30 pulses/sec 60 Hz (25 pulses/sec 50 Hz)
- Up to 150mA
- 10ms pulse width
- 30fps Dynamic digital disk 60 Hz (25 pulses/sec, 50 Hz)
- Recording/playback rate: 1, 2, 4, 8, 15, 30fps 60 Hz (1, 2, 4, 8, 12, 25, 50 Hz)
- Recording time: 10 minutes @ 30fps 60 Hz (time depends on record frame rate) (25 fps, 50 Hz)
- Cardiac Platform with Interventional Vascular Capability:
- Includes all the Vascular MTS features and:
- Cardiac preset imaging profile
- Super “C” configuration (9”/23cm I.I. only)
- Single leaf curved collimator
- Three pedal footswitch
ADDITONAL FEATURES:
- Super-C Configuration:
- Adds Larger “C” for increased orbital rotation (145 degrees)
- Increased Arc Depth (33″ / 838mm)
- MD Configuration:
- Adds motorized movements of c-arm
- Other Image Storage Options:
- CD/DVD Writer digital interface (external)
- Integrated DICOM 3.0 interface
- Hardcopy Options:
- Integrated film/paper printer
- No film developing required
- 8” x 10” (20.3 cm x 25.5 cm) laser quality film/paper
- Multi-format, 1, 2, 4 on 1
- Multi-copy capability
- Thermal printers
- Integrated DICOM interface (storage class/print class/query work-list)
- User Interface:
- Entire system is computer controlled and software upgradeable
- Touchscreen control simplifies operation
- Automated system operation requires minimum operator interface
- Multi-functional controls
- Footswitch
- IR remote (optional)
- Hand-held control
- Simplified keyboard with integrated touchpad
- Multi-purpose image directory
- Retrieve and review images
- Compose hardcopy films
- Copy image
- X-ray dose summary
- Uninterruptible Power:
- Orderly shutdown Electrical
- Input power (60 Hz or 50 Hz) 9900 Elite
- 120V @ 12 A
- 200V, 220V, 230V, 240V @ 10 A
- Regulatory Compliance:
- U.S. 21 CFR Subchapter K
- NFPA 99
- UL 60601-A (CSA/NRTL)
- IEC60601-1 (plus relevant collateral and particular standards)
SPECIFICATIONS:
- Manufacturer: GE
- Part Number (OEM): OEC 9900
- Category: Imaging
- Accessories: None
- Functional Condition: Refurbished
- Cosmetic Condition: Good
- Warranty: 30 Days
- X-Ray System:
- Generator:
- 60kHz high frequency
- 15kW power
- Up to 120kVp
- Up to 75mA for radiographic film exposure
- Continuous high level fluoro (HLF) up to 20mA
- Digital spot up to 75mA
- X-Ray Tube:
- Rotating anode X-ray tube
- 0.3mm and 0.6mm focal spots
- Anode heat capacity: 300,000 HU (per IEC 60613)
- Anode cooling rate: 85,000 HU/min.
- Housing heat capacity: 1,600,000 HU
- Standard housing cooling 15,000 HU/min.
- Passive housing cooling system: 22,500 HU/min. (Standard on 12 inch (31 cm) I.I. systems. Optional on 9 inch (23 cm) systems.
- Digital Image Rotation:
- Digitally adjusts image display
- Automatic image update
- Image rotation
- Image reversal (side-to-side)
- Image invert (top-to-bottom)
- Image positioning without additional exposure
- PreView™ Collimator:
- On-screen collimator position indication
- PreView™ iris collimator
- PreView™ Tungsten rotatable double leaf collimator
- Adjusts collimators without X-ray exposure
- Fluoro Mode:
- kVp range: 40 -120
- mA range: 0.2 – 10 normal mode 1.0 – 20 HLF (high level fluoro)
- Auto and manual fluoro modes
- AutoTrak™ ABS varies mA, kVp, camera gain
- Pulsed Fluoro Mode:
- kVp range: 40 – 120
- mA range: 0.2 – 10
- Pulse rate: 1, 2, 4, 8
- Pulse width: 25 or 50ms
- AutoTrak™ ABS, mA, kVp, camera gain
- Reduces X-ray dose to patient and operator
- High Level Pulsed Fluoro:
- kVp range: 40 – 120
- mA range: 1 – 40
- Pulse rate: 1, 2, 4, 8
- Pulse width: 25 or 50ms
- AutoTrak™ ABS, mA, kVp, and camera gain
- Digital Spot Mode:
-
kVp range: 40 – 120
mA range: Up to 75 - Automatic exposure termination and automatic image save Radiographic Mode
- Radiographic Mode:
- mA range: up to 75
- mAs range: up to 300
- Computer controlled exposure time
- Optional film cassette holder
- 10” x 12” (24cm x 30cm) for 9” I.I.
- 14” x 14” (35cm x 35cm) for 12” I.I.
- Video Imaging System:
- 9″ Image Intensifier:
- Tri-mode 9”/6”/4.5” (23cm/15cm/11cm) image intensifier
- Minimum central resolution (at the monitor):
- 9” (23cm): 2.2 lp/mm
- 6” (15cm): 3.0 lp/mm
- 4.5” (11cm): 3.5 lp/mm
- DQE: 65% (typical)
- 12″ Image Intensifier:
- Tri-mode 12”/9”/6” (31cm/23cm/15cm) image intensifier
- Minimum central resolution (at the monitor):
- 12” (31cm): 1.6 lp/mm
- 9” (23cm): 2.2 lp/mm
- 6” (15cm): 2.6 lp/mm
- DQE: 65% (typical)
-
Precision imaging with Dynamic Range Management (DRM) enhances features of interest while attenuating background noise:
- Preset Imaging Profiles
- 9800
- General
- Orthopedic
- Spine
- Cardiac
- Vascular
- Bolus Chase
- AutoTrak™ Automatic Brightness Stabilization (ABS)
- Automatically seeks the subject anatomy anywhere within the imaging field and selects the optimum imaging technique
- Automatically adjusts to anatomical size and location
- Provides uniform image quality throughout entire image
- Simplifies operation
- Image I.Q.:
- Smart Window
- Dynamically senses the collimator position and automatically adjusts brightness and contrast to produce high image quality.
- Smart Metal
- Allows user to adjust automatic brightness and contrast sensitivity levels to metal
- Provides optimum image quality even when metal is introduced to the field
- Tungsten Collimator
- Denser collimator limits X-ray exposure area
- Reduces scatter radiation
- Improves image detail
-
Video Camera:
- High resolution 1k x 1k CCD camera
- Full frame capture
- Motorized rotation
- On-screen orientation indicator (real-time feedback without fluoro)
- Left-right image reversal
- Top-bottom image invert
- Video Display:
- Dual 18” (46cm) display anti-glare, LCD flat panel monitors mounted on an articulating arm
- 22” horizontal travel
- 7° up/10° down
- Monitors viewable from all four sides of workstation
- Horizontal and vertical viewing angle 170°
- 700 CD/M2 maximum brightness
- Touch screen system control
- 1280 x 1024 high resolution monitors
- Ambient room-light compensation
-
Integrated color monitor for display of VGA, DVI, DVI-D, S-VHS, and SDI-SD formats (optional)
In addition, please acknowledge the following disclaimer:
* IMPORTANT - PLEASE READ BEFORE PURCHASING! * All pictures of items being sold are used for reference purposes and are described as accurately as possible. If there is an error in a listing, we will try and resolve any issues to the best of our abilities that may arise before or after a sale. Complete units all come with a power cord and DO NOT come with any cables, sensors, manuals, accessories etc. unless otherwise noted in the description.
Purchaser agrees that seller is not liable for any injuries or damages of any kind associated in any way with this equipment. Purchaser agrees to indemnify and hold harmless seller and seller's officers, directors, employees, agents, and shareholders against any and all claims, liabilities, obligations, demands, cost and expenses of every kind and nature, including but not limited to attorney's fees and litigation expenses, from or related to the equipment and any use thereof.
* NOTE - FDA Regulation and Certification: "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item."